Silicon Labs /Series1 /EFR32MG1B /EFR32MG1B132F256GJ43 /CMU /HFXOCTRL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as HFXOCTRL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (MODE)MODE 0 (AUTOCMD)PEAKDETSHUNTOPTMODE 0 (LOWPOWER)LOWPOWER 0 (XTI2GND)XTI2GND 0 (XTO2GND)XTO2GND 0 (0CYCLES)LFTIMEOUT 0 (AUTOSTARTEM0EM1)AUTOSTARTEM0EM1 0 (AUTOSTARTSELEM0EM1)AUTOSTARTSELEM0EM1

PEAKDETSHUNTOPTMODE=AUTOCMD, LFTIMEOUT=0CYCLES

Description

HFXO Control Register

Fields

MODE

HFXO Mode

PEAKDETSHUNTOPTMODE

HFXO Automatic Peak Detection and Shunt Current Optimization Mode

0 (AUTOCMD): Automatic control of HFXO peak detection and shunt optimization sequences. CMU_CMD HFXOPEAKDETSTART and HFXOSHUNTOPTSTART can also be used.

1 (CMD): CMU_CMD HFXOPEAKDETSTART and HFXOSHUNTOPTSTART can be used to trigger peak detection and shunt optimization sequences.

2 (MANUAL): CMU_HFXOSTEADYSTATECTRL IBTRIMXOCORE, REGISH, REGSELILOW, and PEAKDETEN are under full software control and are allowed to be changed once HFXO is ready.

LOWPOWER

Low Power Mode Control

XTI2GND

Clamp HFXTAL_N Pin to Ground When HFXO Oscillator is Off

XTO2GND

Clamp HFXTAL_P Pin to Ground When HFXO Oscillator is Off

LFTIMEOUT

HFXO Low Frequency Timeout

0 (0CYCLES): Timeout period of 0 cycles (disabled)

1 (2CYCLES): Timeout period of 2 cycles

2 (4CYCLES): Timeout period of 4 cycles

3 (16CYCLES): Timeout period of 16 cycles

4 (32CYCLES): Timeout period of 32 cycles

5 (64CYCLES): Timeout period of 64 cycles

6 (1KCYCLES): Timeout period of 1024 cycles

7 (4KCYCLES): Timeout period of 4096 cycles

AUTOSTARTEM0EM1

Automatically Start of HFXO Upon EM0/EM1 Entry From EM2/EM3

AUTOSTARTSELEM0EM1

Automatically Start and Select of HFXO Upon EM0/EM1 Entry From EM2/EM3

Links

() ()